Skip to content

Waste Incinerator

Get in touch with HICLOVER: +8613813931455 (Mobile/WhatsApp)|www.haiwos.net

Menu
  • Home
    • About
    • Air Filters
    • Ebola Incinerator
    • Russia Incinerator
    • Incinerator Blog
  • HICLOVER Incinerators
    • Twitter
    • Wastecos
    • Youtube
    • Somali Incinerator
    • Facebook
  • Waste Incinerator
    • Sudan Incinerator
    • Ethiopia Incinerator
  • Blogs
    • Gallery
    • Mali Incinerator
    • News
    • Rwanda Incinerator
    • Iraq Incinerator
    • Medical Waste Incinerator
  • Contact
    • Buy Online
    • Afghanistan Incinerator
    • Espanol
    • Francais
    • Tanzania Incinerator
  • Store

Tag: Medical

HICLOVER Mobile Containerized Incinerators

No Comments
| high temperature incinerator

a. be based on common, well-proven and clean technology – both as a complete unit and in terms of its individual components. b. be very robust, sturdy and capable of installation in remote locations subject to severe conditions. d. generate residual incinerator ash conforming to <10% by volume and <25% by weight of the waste […]

Read More »

DOMESTIC INCINERATOR, YD 300 Spare Parts for Waste Incinerators and Burners

No Comments
| high temperature incinerator

  incineradores de residuos para fabricantes de uso general y municipal en paraguay concept of incinerator machine     Ceramic filter candle 1mtr Filter-Candle Sick sensor encoder BCG13-L1KM05PP LID REPAIR KIT I8-1000 I8-1000 Lid Repair Kit SS Chimney SS Chimney SS Chimney extension SS Chimney extension SS Chimney Cowl SS Chimney Cowl Refractory cement CA50-A600 Asbestos rope 20425159188 Ignition transformer-secondary burner EB14HPM Ignition transformer-Primary burner 26-48-3371T Emergency push button […]

Read More »

Containerized Mobile Incinerator

No Comments
| high temperature incinerator

  Containerized Mobile Incinerator͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ […]

Read More »

Model TS10 Incinerator with wet scrubber (Spray Tower) and Defogging Tower

No Comments
| high temperature incinerator

  Model TS10 Incinerator with wet scrubber (Spray Tower) and Defogging Tower Incinerator Items/Model HICLOVER TS10(PLC)   Burn Rate (Average) 10-20 kg/hour Feed Capacity(Average) 20kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 3.0Kw Burner Type Italy Brand Oil […]

Read More »

large scale incinerator

No Comments
| high temperature incinerator

Primary Combustion Chamber Secondary Combustion Chamber Smoke Filter Chamber Incinerator PLC Control Case Chimney:6.0Meters  *(upgrade to Stainless Steel, free cost) Italy oil burner: 04 sets Oil Tank (if oil fuel): 800Liters The secondary chamber must comply with the following minimum criteria: “• Heavy steel construction small scale incinerators incinerator burner • An excess air and high temperature operational mode. • Sufficient size and appropriate geometry to achieve a gas temperature of at least 1000 Celsius for a retention time of at least 2 seconds when pre-heated and correctly operated. • Sufficient forced air inflow and airflow and fuel supply controls to ensure an exhaust gas oxygen content range of 6-12% at all times.  • Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm.  • Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm.  • Refractory lining of all the ducts shall be done with refractory castings. Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints • An electrically powered fan forced air supply, with the capacity for variation by the operator. • One or more fuel burners designed to use diesel fuel type 2 (vehicle standard) equipped with a spark igniter.   • A digital thermometer with connected to an electronic datalogger. The thermometer shall be located on the chamber wall away from the fuel burner. Medical Waste Incineration Treatment Average 1000-1500 kg/hour Average 6000kg/feeding PLC(Programmable Logic Controller Incinerator) 4800Liter A heat exchanger to pre-heat air destined for the primary chamber is not compulsory but recommended.  The combustion air systems and fans shall be designed to ensure high combustion efficiency and avoid a reducing (corrosive) atmosphere, incomplete burnout of the flue gases and related problems. It should also be possible to heat the primary air from 10°C to approximately 145°C, depending on the waste composition and moisture content. “The incinerator shall be designed and equipped to be installed, commissioned and operated in such a way as to prevent emissions into the air giving rise to significant ground-level air pollution; in particular, exhaust gases shall be discharged in a controlled fashion by means of a stack the height of which is calculated in such a way as to safeguard human health and the environment. All incinerators shall meet the following emission and operating standards: • Combustion efficiency (C.E.) shall be at least 99.0% • The combustion efficiency shall be computed as follows: • The diameter of the stack shall be selected by the Contractor to deliver an exhaust exit velocity of not less than 10 metres per second vertically upwards when at full scale operation. • An emission stack sampling port shall be included immediately above the secondary chamber. ” Controlled hygienic, mechanical or automatic feeding methods must not negatively influence the air supply and temperature in the primary and secondary chambers of the incinerator. “Each unit shall include a diesel fuel storage tank of sufficient capacity to enable operation of the unit for 5 working days of 10 hours each. • The unit shall include a pumping system and lines to supply the burners from the tank and the diesel-electric generator.  The pumping system will have two pumps in parallel for redundancy. • The supply lines will be fabricated from steel tubing and adequately protected and supported against damage during operations and include shutoff valves for each line.  • The unit shall be equipped with a fuel meter. “Incinerators must  be able to support different power sources (PV solar system , diesel Electric generator , local or  compound mini-scale grid) The proposed incinerators shall be able to be completely packed into a series of 20ft export standard sea containers. All electrical connections attached with the incinerator and other machinery should be provided with suitable and necessary safety devices and be protected by steel conduits, cable trays, and supports. The manufacturer should permanently mark on the incinerator indicating: (i) manufacturer’s name or trademark (ii) style, type, model or, date of manufacture of the incinerator (iii) capacity in terms of net designed heat release in heat units per timed period (i.e., British Thermal Units per hour, mega joules per hour, kilocalories per hour). “The unit shall be supplied with a lockable operations store, that shall be initially supplied with the following consumables: • A first aid kit, suitable for addressing the hazards presented by the unit. • 5 full sets of personal protective clothing and equipment. • Operating logbooks. […]

Read More »

Posts pagination

Previous 1 2 3 … 12 Next

www.clover-incinerator.com

HICLOVER.COM

https://www.youtube.com/watch?v=BxiEa3XYvBs

Contact Us

Tel: +86-25-8461 0201
Mobile: +86-138139 31455
WhatsApp: 008613813931455
Twitter ID: @hiclovercom
Wechat: 008613813931455
Website1: www.hiclover.com
Website2: www.clover-incinerator.com
Email1: [email protected]
Email2: [email protected]
Email3: [email protected]
Email4: [email protected]

Incinerator Video

https://www.youtube.com/watch?v=CDdacp1wk1A

Medical Environmental

Waste Incinerator

Recent Posts

  • HICLOVER TS20: Eficiencia y Seguridad con un Incinerador de Carga Superior
  • Airport and Aviation Maintenance Waste Incineration Solutions
  • High-Temperature Animal Incinerators for the Food Processing & Slaughter Industry
  • Sustainable Animal Waste Incineration Solutions in Africa: HICLOVER Expands Its Reach
  • HICLOVER Medical Waste Incinerators for Afghanistan’s Expanded Immunization Program
  • HS CODE 84178050 for Waste Incinerators
  • HICLOVER TS50 PLC Animal Waste Diesel-Fired Incinerator Top Loading
  • Small-Scale Medical Waste Incinerators in Togo
  • HICLOVER Containerized Incinerators for Biohazard Waste Treatment
  • HICLOVER TS200 PLC Incinerator: Advanced Waste Disposal Solution Tailored for South Sudan
  • Incinérateur de déchets médicaux au Bénin
  • Small Medical Waste Incinerators in Rwanda
  • Advanced Waste Solutions for Libya’s Oil Fields
  • What’s Model of Hospital Incinerator for 240-bed hospital in Algeria
  • how to manage hospital waste
  • TECHNICAL SPECIFICATIONS FOR INCINERATOR– 50 KGS/HR
  • PLC based control box for incinerator
  • HOSPITAL WASTE INCINERATOR incineration Secondary Chamberincineration Secondary Chamber
  • Medical Waste Incineration and Medical Incinerators
  • HOSPITAL WASTE INCINERATOR hospital waste management system
  • discuss the design and operation or various types of incinerators
  • clinical waste treatment 5kgs 10kgs 20kgs and 30kgs per hour average
  • HICLOVER Mobile Containerized Incinerators
  • DOMESTIC INCINERATOR, YD 300 Spare Parts for Waste Incinerators and Burners
  • Containerized Mobile Incinerator
  • Model TS10 Incinerator with wet scrubber (Spray Tower) and Defogging Tower
  • large scale incinerator
  • double chamber incinerator
  • General waste incinerator with automated feeding system
  • Industrial hazardous and nonhazardous waste and medical infectious waste
  • industrial waste incinerator
  • Vertical closed incinerator combustion chamber
  • Waste Incinerator Capacity average 30-50 kgs per hour
  • Waste Incinerator HICLOVER TS100
  • Incinerator Items/Model HICLOVER TS20(PLC)
  • HICLOVER TS300(PLC) PLC Automatic Waste Incinerator
  • INDUSTRIAL WASTE INCINERATORS FOR ALL SITES
  • Medical waste incinerator Burning Rate 100kg/hr
  • Waste Incinerator YD500(PLC) and YD600(PLC)
  • medical wasteincinerator manufacturers
  • incinerator for hospital
  • Repair hospital incinerator
  • TS30 Model Waste Incinerators
  • BANGLADESH Incinerator (Model TS20 Gas with wet scrubber)
  • Trinidad and Tobago INCINERATOR.Q&A
  • Municipal waste incinerator
  • Drum type incinerator
  • CONTAINERIZED INCINERATOR
  • WASTE INCINERATOR TREATMENT – TS300( PLC)
  • spare parts for Rilleo burners

Tags

animal incinerators china waste incinerator container Incinerator domestic incinerator from:hiclovercom garbage incinerator garbage incinerators general waste incinerator hospital incinerators incinerador incinerate incineration of medical waste incineration of solid waste incineration process incinerator incinerator for sale incinerator manufacturer incinerator manufacturers incinerator price incinerators incinerators china incinerators for sale industrial waste incinerator laboratory incinerator large scale incinerator Medical medical incinerator medical incinerator manufacturers medical waste medical waste incineration medical waste incinerator medical waste incinerator for sale medical waste incinerators Mobile Incinerator municipal solid waste incinerators municipal waste incinerator pathological waste incinerator portable incinerator small incinerator solid waste incinerator solid waste incinerators waste waste incineration waste incinerator waste incinerators

HICLOVER.COM

Waste Incinerator 2025 . Powered by WordPress