HICLOVER TS200 PLC Incinerator: Advanced Waste Disposal Solution Tailored for South Sudan
In recent years, South Sudan has faced increasing pressure to improve its waste management, particularly for medical waste, humanitarian camp waste, and other high-density refuse. The HICLOVER TS200 PLC incinerator is an industrial-grade solution engineered to meet exactly these challenges, combining advanced technology, reliability, and local adaptability.
This article highlights how the HICLOVER TS200 PLC aligns perfectly with South Sudan’s unique needs, its key technical specifications, and why it is the smart choice for hospitals, refugee camps, NGOs, and governmental projects.
Designed for Heavy-Duty Operation in Demanding Environments
The HICLOVER TS200 PLC is built for a burn rate of around 180 kg/hour, supported by a large primary combustion chamber of 1.98 m³ and a secondary chamber of 0.8 m³. This large capacity ensures it can handle high daily waste volumes typical of large hospitals, refugee camps, and urban waste centers.
Its manual feed mode combined with a top-loading door (1300x1000mm) allows operators to load large quantities (average 200–250 kg per feeding) safely and efficiently. This design works well even when electrical infrastructure is unstable—a common issue in South Sudan.
PLC Automatic Control & Intelligent Safety Features
At the heart of this model lies a fully automated PLC control system, featuring:
-
Temperature monitoring with a corundum probe (rated up to 1600°C).
-
Automatic high-temperature retention: keeps 1st chamber at 800–1000°C and 2nd chamber at 1000–1300°C.
-
Automatic fuel-saving mode.
-
Automatic cooling and false alarm systems with display, voice, and light alerts.
-
3.7-inch LCD screen for real-time status updates.
-
System testing mode & time setting to support routine safety checks.
These intelligent functions protect operators, improve burn efficiency, and reduce fuel consumption—essential for remote areas where diesel or LPG supply can be limited or costly.
Engineered for Local Needs in South Sudan
Fuel Flexibility:
-
Uses diesel (avg. 22 kg/hour) or natural gas (approx. 25 m³n/hour).
-
Comes with a 400L oil tank and liquid level display for easy onsite fuel management.
Robust Construction:
-
Refractory lined chimney (1 meter) and stainless steel chimney (8 meters), ideal for withstanding harsh outdoor conditions.
-
Hot face of the combustion chambers is lined with high alumina refractory bricks (≥115 mm thickness, 65% Al₂O₃, 1750°C grade).
-
Cold face lined with high-rate refractory ceramic fiber for insulation.
Protection & Maintenance:
-
Automatic on/off Italy brand burners reduce manual intervention.
-
Sealing materials are heat-resistant ceramic fiber, ensuring minimal heat loss and maximum safety.
-
External paint rated for 250°C protects the steel body from rust and weather.
Compact & Upgradeable Design
The TS200 PLC’s design makes it highly adaptable:
-
External dimensions: 3800x1700x1600mm (without chimney).
-
Gross weight: ~8000 kg—heavy-duty yet still movable using flatbeds or cranes.
-
Containerized mobile option: For field hospitals, UN camps, or mining sites.
-
Wet scrubber (optional): For reducing flue gas pollutants and meeting stricter environmental standards.
-
Front or side loading doors (optional): To suit different waste logistics setups.
Certifications & Compliance
The HICLOVER TS200 PLC is fully certified:
-
CE certificates: CE(2006/42/EC, 2014/30/EU).
-
ISO9001:2015 certified manufacturing.
-
Recognized as a High-tech Enterprise.
This ensures it meets international safety, quality, and environmental compliance—a critical factor for projects supported by global NGOs, UN agencies, and international donors.
Practical Efficiency & Local Suitability
Residency time of 2 seconds in the secondary chamber ensures full combustion, minimizing harmful emissions—important for environmental health in populated camps or hospitals.
Temperature protection and automatic shutdown features protect the system and staff against overheating and mechanical faults—vital in regions with limited technical support.
Its combination of large capacity, automatic control, intelligent fuel saving, and safety features offers a low running cost per ton of waste, making it sustainable even in South Sudan’s challenging economic context.
Environmental Commitment
Optional wet scrubbers help reduce emissions further, aligning with rising international environmental standards and local air quality goals.
The high combustion temperature range (up to 1300°C) ensures complete destruction of pathogens in medical waste—critical for public health.
Why Choose HICLOVER TS200 PLC for South Sudan?
-
High capacity for large hospitals & camps.
-
Automatic PLC control minimizes skilled labor dependency.
-
Fuel-saving intelligent mode lowers operational costs.
-
Designed to handle unstable electricity & fuel supply.
-
CE & ISO certified—ready for donor-funded or NGO projects.
-
Containerized and mobile options to reach remote areas.
Contact HICLOVER
For more details about the TS200 PLC incinerator or to discuss project-specific needs in South Sudan, please visit:
www.hiclover.com
Email: [email protected]
-
South Sudan incinerator
-
medical waste incinerator for Africa
-
containerized incinerator South Sudan
-
high capacity incinerator TS200 PLC
-
PLC automatic incinerator
-
HICLOVER waste management solutions