Skip to content

Waste Incinerator

Get in touch with HICLOVER: +8613813931455 (Mobile/WhatsApp)|www.haiwos.net

Menu
  • Home
    • About
    • Air Filters
    • Ebola Incinerator
    • Russia Incinerator
    • Incinerator Blog
  • HICLOVER Incinerators
    • Twitter
    • Wastecos
    • Youtube
    • Somali Incinerator
    • Facebook
  • Waste Incinerator
    • Sudan Incinerator
    • Ethiopia Incinerator
  • Blogs
    • Gallery
    • Mali Incinerator
    • News
    • Rwanda Incinerator
    • Iraq Incinerator
    • Medical Waste Incinerator
  • Contact
    • Buy Online
    • Afghanistan Incinerator
    • Espanol
    • Francais
    • Tanzania Incinerator
  • Store

Category: waste-incinerator

islands incinerators

No Comments
| waste-incinerator

Application : four islands in Croatia Capacity/island : 4000 kg/day ; 25000 kg/day ; 31000 kg/day ; 48000 kg/day Burning temperature – over 12000C Two chambers – minimum Emissions – dioxin and heavy metaly – better then Kyoto protocol Emission – monitoring system Waste unloiding – directly from waste track to incinerator Burn Rate(Average kgs/hr)  25 kg   primary chamber  800 degree   secondary chamber  1000 degree   chimney  standard   shredder  separately   Autoclave or microwaves  separately   temperature monitor  attached outside of machine operating  Fuel and electric   –          Toxic and dangerous wastes,   –          Medical pharmaceutical and hospitable liquids  Wastes –          Domestic garbage   –          Electric and electronic wastes –          Industrial wastes –          In General, all type of wastes and garbages 1) working now in new order for Nigeria though our company for Yd-300 x 2 units , this is a job in hand in our customer located in dubai 2) the customer also want also to buy a fuel bulk storage tank  to be for 3 days continuous operation so we hope also you can manufacture it so please give me the best price for fuel bulk storage tank  to be for 3 days continuous operation for YD-300 3) installation must be in the site in Nigeria by your company ,as i know your price rate which you sent to be before 4) what is the best price CIF Nigeria in lagos sea port as i have only price for cif dubai 5) 150 pcs Waste Containers (820 L) fully compatible with the incinerator and clinical waste container washing system.  please send me the price and catalog for this item 6) also they need Automatic Clinical Waste Container Washing System complete in every respect and fully compatible with containers price and catalog 7) 2 units 1.5 tonne Fork Lift  ( if you know good price and quality  company in china) 8) 1 unit Clinical Waste Container Vehicles complete in every respect and fully compatible with containers. 9) Spare Parts For 2 Years Operation & Maintenance  for YD-300 and for the above machines 10) all parts , pipe work electrical work and civil work for incinerator must be provided and material must be quoted The highest temperature that the filter bag can operate continuously is 260C.    In order to add a bag house using our filter products,  you would need to add a water cooling tower or other method to reduce the inlet temperature at the baghouse to less than 260C.    If you cannot lower the temperature below 260C, then we cannot utilize our membrane filter bags.   Related posts: 1. N95 and […]

Read More »

new hospital waste treatment plant

No Comments
| waste-incinerator

We are in the process of building a new hospital waste treatment plant and we are evaluating different technologies from around the world.  We are looking to incinerate approx. 1 to 2 tons of biomedical waste per day using LPG for heating.  Please send me all general information and quotes for machines of all ranges that could meet our needs.  Also, please include emissions reports of all of the various machines that could be of interest to us especially with regards to  dioxins and furals as well as lists of recommendations from past clients.  If you have any government entities using your machines please include lists of whom they are as well as any documentation that you contain that can prove their use.  Timing is also very important to us with regards of when the machines can arrive to Peru and be up and running. Therefore, it would be appreciated if you could include time frames and the whole process from purchase to installation and maintenance.  Burning Rate:5–120kg/hour Minimum Operating Temperature:850o C(primary combustion) Maximum Operating Temperature:1450 oC(Afterburner chamber) Secondary Burning Capacity:Compulsory Density Insulation:20mm High Refractory Casting:Minimum 65mm Heavy duty refracting lining to withstand:1500 oC Average burn out time :maximum:3 hrs Fuel type:Diesel Fuel Consumption in L/hr:7.5 to 9 Residence time in secondary chamber:2sec Residue ash pot 100kg:Max 3.8kg Related posts: Municipal Waste Incinerator Clover Medical Medical West Incinerator Medical Waste Diesel Incinerator 100 Kg GmbH Incinerator Furnaces for Pet Cremation

Read More »

new hospital waste treatment plant

No Comments
| waste-incinerator

We are in the process of building a new hospital waste treatment plant and we are evaluating different technologies from around the world.  We are looking to incinerate approx. 1 to 2 tons of biomedical waste per day using LPG for heating.  Please send me all general information and quotes for machines of all ranges that could meet our needs.  Also, please include emissions reports of all of the various machines that could be of interest to us especially with regards to  dioxins and furals as well as lists of recommendations from past clients.  If you have any government entities using your machines please include lists of whom they are as well as any documentation that you contain that can prove their use.  Timing is also very important to us with regards of when the machines can arrive to Peru and be up and running. Therefore, it would be appreciated if you could include time frames and the whole process from purchase to installation and maintenance.  Burning Rate:5–120kg/hour Minimum Operating Temperature:850o C(primary combustion) Maximum Operating Temperature:1450 oC(Afterburner chamber) Secondary Burning Capacity:Compulsory Density Insulation:20mm High Refractory Casting:Minimum 65mm Heavy duty refracting lining to withstand:1500 oC Average burn out time :maximum:3 hrs Fuel type:Diesel Fuel Consumption in L/hr:7.5 to 9 Residence time in secondary chamber:2sec Residue ash pot 100kg:Max 3.8kg Related posts: Technical Requirements for Medical Waste Incinerator Incinerator Double Burner with 50 Kg/Hr Capacity Hospital Incinerators 50 Kg/Hr Capacity Waste Clinic Incinerator

Read More »

PRINCE SALMAN UNIVERSITY HOSPITAL (MINISTRY OF EDUCATION) @ AL KHARJ

No Comments
| waste-incinerator

 ملاحظة: المخططات المقدمة هي بغرض التسعير وعلى المقاول تقديم مخططات متكاملة  طبقا لتوصيات الشركة المصنعة وبما يلزمها من ملحقات لعمل الوحدات بصورة سليمة، ويتم التنسيق مع الوزارة لتحديد مكان الوحدة بالموقع العام  توريد وتركيب واختبار محرقة نفايات طبيه بسعة 75  كجم / الساعة تعمل بالغاز ( LPG ) كاملة بجميع مشتملاتها وملحقاتها مع المدخنة طبقاً للمواصفات الفنية والشروط الصحية العامة   إنشاء غرفه خاصة بالمحرقة تتسع لثلاث محارق كما فى البند 3-1-1 وملحق بغرفة المحرقة مخزن للنقايات يستوعب نفايات لمدة  سبعة أيام وتكون جميع الانشاءات من الخرسانة المسلحة مع تجهيز مبنى المحرقة والمخزن بجميع أعمال التوصيلات والكهربائية والاضاءة وأنظمة التغذية بالمياه والصرف  تزويد مبنى المحرقة ومستودع النفايات بنظام اطفاء حريق بالرشاشات يعتمد على مصدر المياه من شبكة الموقع العام وكذلك نظام إنذار حريق يحتوى على حساسات للحرارة والدخان ويكون هذا النظام مرتبط مع أنظمة إنذار الحريق بالمستشفى  توريد وتركيب واختبار نظام تهوية جبرية لغرفة المحرقة والمستودع بواسطة مراوح مركزية ROOF TOP EXHAUET FANS مع تزويدها بفلاتر عالية الكفاءة ( HEPA FILTER  تركب على سحب المراوح مع اخذ معدل تغيير الهواء 5 مرات فى الساعة مع مجارى وجربلات الهواء المطلوبة  توريد وتركيب وإختبار وحدة تكييف منفصلة لمستودع النفايات DUCTED SPLIT UNITES وبسعة كافية للمحافظة على درجة الحرارة الداخلية عند 14 درجة مئوية صيفاً وشتاً  توريد وتركيب وإختبار مخزن تبريد من الحوائط المعزولة سابقة التحهيز بداخل غرفة النفايات وبسعة 35 متر مكعب لحفظ النفايات الطبية في درجة حرارة صفر مئوي لحين حرقها شاملة لوحدة التبريد وجميع الملحقات      BIO MEDICAL INCENERATOR  BIO MEDICAL INCENERATOR  PLANT Fabricating, supplying, installing and commissioning including all assosaries such as controling and measuring devices, all civil works as needed either in concrete or masonary as the case may be necessary room stack height etc as per the indicated requirment in the specification. if any thing is left out, the bidder is required to include the same to make the system complete for treating biomedical waste generated in hospital having bed of 250nos. etc. CAPACITY :- 200BEDS. Operation and Maintenance Manual As built Drawing in 3 set hard copy + Soft copy in Cad Testing and Commissioning  Note: The drawings  are provided for the purpose of pricing and the contractor has to provide an integrated drawings in accordance with the manufacturer’s recommendations and with the necessary addendums  to the work of the units properly, and be coordinated with the ministry to locate the unit place in the general site  Supply, installation and testing of medical waste incinerator with a capacity of 75 kg / hr gas (LPG) complete with all accessories and consequently with the chimney in accordance with the technical specifications and conditions of public health  make a room for the incinerator that  accommodate three incinerators as in item 3.1.1 and attached to the  incinerator room   waste store that accommodate waste for a period of seven days and all the constructions of reinforced concrete with  preparingg  incinerator building  and store with all the work of wiring, electrical and lighting systems, water supply and sanitation   supply incinerator building and the waste warehouse with   a fire extinguish sprinkler system depends on the source of the water from network of teh general site , as well as a fire alarm system contains sensors for heat, smoke and  this system is linked with the hospital fire alarm systems  Supply, installation and testing of the ventilation system of the  incinerator room and the warehouse with  fans ROOF TOP EXHAUET FANS providing them with filters with high efficiency (HEPA FILTER ride to pull fans with taking the air change rate of 5 times per hour with streams and air required grilles    Supply, installation, testing separate conditioning unit for  waste repository DUCTED SPLIT UNITES and capacity sufficient to maintain the internal temperature at 14 degrees Celsius in summer and winter   Supply, installation, testing  of the cooling store of  insulated  prefabricated walls   inside the waste  room with a capacity of   35 cubic meters to save the medical waste at a temperature of zero Celsius till  burning  including the  cooling unit and all accessories  Related posts: Incinerator Medical Waste Incinerators Animal Crematorium Incinerators Rated for 60 Pounds Per Hour Pet Cremation Equipments

Read More »

PRINCE SALMAN UNIVERSITY HOSPITAL (MINISTRY OF EDUCATION) @ AL KHARJ

No Comments
| waste-incinerator

 ملاحظة: المخططات المقدمة هي بغرض التسعير وعلى المقاول تقديم مخططات متكاملة  طبقا لتوصيات الشركة المصنعة وبما يلزمها من ملحقات لعمل الوحدات بصورة سليمة، ويتم التنسيق مع الوزارة لتحديد مكان الوحدة بالموقع العام  توريد وتركيب واختبار محرقة نفايات طبيه بسعة 75  كجم / الساعة تعمل بالغاز ( LPG ) كاملة بجميع مشتملاتها وملحقاتها مع المدخنة طبقاً للمواصفات الفنية والشروط الصحية العامة   إنشاء غرفه خاصة بالمحرقة تتسع لثلاث محارق كما فى البند 3-1-1 وملحق بغرفة المحرقة مخزن للنقايات يستوعب نفايات لمدة  سبعة أيام وتكون جميع الانشاءات من الخرسانة المسلحة مع تجهيز مبنى المحرقة والمخزن بجميع أعمال التوصيلات والكهربائية والاضاءة وأنظمة التغذية بالمياه والصرف  تزويد مبنى المحرقة ومستودع النفايات بنظام اطفاء حريق بالرشاشات يعتمد على مصدر المياه من شبكة الموقع العام وكذلك نظام إنذار حريق يحتوى على حساسات للحرارة والدخان ويكون هذا النظام مرتبط مع أنظمة إنذار الحريق بالمستشفى  توريد وتركيب واختبار نظام تهوية جبرية لغرفة المحرقة والمستودع بواسطة مراوح مركزية ROOF TOP EXHAUET FANS مع تزويدها بفلاتر عالية الكفاءة ( HEPA FILTER  تركب على سحب المراوح مع اخذ معدل تغيير الهواء 5 مرات فى الساعة مع مجارى وجربلات الهواء المطلوبة  توريد وتركيب وإختبار وحدة تكييف منفصلة لمستودع النفايات DUCTED SPLIT UNITES وبسعة كافية للمحافظة على درجة الحرارة الداخلية عند 14 درجة مئوية صيفاً وشتاً  توريد وتركيب وإختبار مخزن تبريد من الحوائط المعزولة سابقة التحهيز بداخل غرفة النفايات وبسعة 35 متر مكعب لحفظ النفايات الطبية في درجة حرارة صفر مئوي لحين حرقها شاملة لوحدة التبريد وجميع الملحقات      BIO MEDICAL INCENERATOR  BIO MEDICAL INCENERATOR  PLANT Fabricating, supplying, installing and commissioning including all assosaries such as controling and measuring devices, all civil works as needed either in concrete or masonary as the case may be necessary room stack height etc as per the indicated requirment in the specification. if any thing is left out, the bidder is required to include the same to make the system complete for treating biomedical waste generated in hospital having bed of 250nos. etc. CAPACITY :- 200BEDS. Operation and Maintenance Manual As built Drawing in 3 set hard copy + Soft copy in Cad Testing and Commissioning  Note: The drawings  are provided for the purpose of pricing and the contractor has to provide an integrated drawings in accordance with the manufacturer’s recommendations and with the necessary addendums  to the work of the units properly, and be coordinated with the ministry to locate the unit place in the general site  Supply, installation and testing of medical waste incinerator with a capacity of 75 kg / hr gas (LPG) complete with all accessories and consequently with the chimney in accordance with the technical specifications and conditions of public health  make a room for the incinerator that  accommodate three incinerators as in item 3.1.1 and attached to the  incinerator room   waste store that accommodate waste for a period of seven days and all the constructions of reinforced concrete with  preparingg  incinerator building  and store with all the work of wiring, electrical and lighting systems, water supply and sanitation   supply incinerator building and the waste warehouse with   a fire extinguish sprinkler system depends on the source of the water from network of teh general site , as well as a fire alarm system contains sensors for heat, smoke and  this system is linked with the hospital fire alarm systems  Supply, installation and testing of the ventilation system of the  incinerator room and the warehouse with  fans ROOF TOP EXHAUET FANS providing them with filters with high efficiency (HEPA FILTER ride to pull fans with taking the air change rate of 5 times per hour with streams and air required grilles    Supply, installation, testing separate conditioning unit for  waste repository DUCTED SPLIT UNITES and capacity sufficient to maintain the internal temperature at 14 degrees Celsius in summer and winter   Supply, installation, testing  of the cooling store of  insulated  prefabricated walls   inside the waste  room with a capacity of   35 cubic meters to save the medical waste at a temperature of zero Celsius till  burning  including the  cooling unit and all accessories  Related posts: Diesel Fuel Incinerator Medical Waste Incinerator Medical Waste Incinerator Oil Waste Incinerator

Read More »

Posts pagination

Previous 1 2 3 … 349 Next

www.clover-incinerator.com

HICLOVER.COM

https://www.youtube.com/watch?v=BxiEa3XYvBs

Contact Us

Tel: +86-25-8461 0201
Mobile: +86-138139 31455
WhatsApp: 008613813931455
Twitter ID: @hiclovercom
Wechat: 008613813931455
Website1: www.hiclover.com
Website2: www.clover-incinerator.com
Email1: [email protected]
Email2: [email protected]
Email3: [email protected]
Email4: [email protected]

Incinerator Video

https://www.youtube.com/watch?v=CDdacp1wk1A

Medical Environmental

Waste Incinerator

Recent Posts

  • HICLOVER TS20: Eficiencia y Seguridad con un Incinerador de Carga Superior
  • Airport and Aviation Maintenance Waste Incineration Solutions
  • High-Temperature Animal Incinerators for the Food Processing & Slaughter Industry
  • Sustainable Animal Waste Incineration Solutions in Africa: HICLOVER Expands Its Reach
  • HICLOVER Medical Waste Incinerators for Afghanistan’s Expanded Immunization Program
  • HS CODE 84178050 for Waste Incinerators
  • HICLOVER TS50 PLC Animal Waste Diesel-Fired Incinerator Top Loading
  • Small-Scale Medical Waste Incinerators in Togo
  • HICLOVER Containerized Incinerators for Biohazard Waste Treatment
  • HICLOVER TS200 PLC Incinerator: Advanced Waste Disposal Solution Tailored for South Sudan
  • Incinérateur de déchets médicaux au Bénin
  • Small Medical Waste Incinerators in Rwanda
  • Advanced Waste Solutions for Libya’s Oil Fields
  • What’s Model of Hospital Incinerator for 240-bed hospital in Algeria
  • how to manage hospital waste
  • TECHNICAL SPECIFICATIONS FOR INCINERATOR– 50 KGS/HR
  • PLC based control box for incinerator
  • HOSPITAL WASTE INCINERATOR incineration Secondary Chamberincineration Secondary Chamber
  • Medical Waste Incineration and Medical Incinerators
  • HOSPITAL WASTE INCINERATOR hospital waste management system
  • discuss the design and operation or various types of incinerators
  • clinical waste treatment 5kgs 10kgs 20kgs and 30kgs per hour average
  • HICLOVER Mobile Containerized Incinerators
  • DOMESTIC INCINERATOR, YD 300 Spare Parts for Waste Incinerators and Burners
  • Containerized Mobile Incinerator
  • Model TS10 Incinerator with wet scrubber (Spray Tower) and Defogging Tower
  • large scale incinerator
  • double chamber incinerator
  • General waste incinerator with automated feeding system
  • Industrial hazardous and nonhazardous waste and medical infectious waste
  • industrial waste incinerator
  • Vertical closed incinerator combustion chamber
  • Waste Incinerator Capacity average 30-50 kgs per hour
  • Waste Incinerator HICLOVER TS100
  • Incinerator Items/Model HICLOVER TS20(PLC)
  • HICLOVER TS300(PLC) PLC Automatic Waste Incinerator
  • INDUSTRIAL WASTE INCINERATORS FOR ALL SITES
  • Medical waste incinerator Burning Rate 100kg/hr
  • Waste Incinerator YD500(PLC) and YD600(PLC)
  • medical wasteincinerator manufacturers
  • incinerator for hospital
  • Repair hospital incinerator
  • TS30 Model Waste Incinerators
  • BANGLADESH Incinerator (Model TS20 Gas with wet scrubber)
  • Trinidad and Tobago INCINERATOR.Q&A
  • Municipal waste incinerator
  • Drum type incinerator
  • CONTAINERIZED INCINERATOR
  • WASTE INCINERATOR TREATMENT – TS300( PLC)
  • spare parts for Rilleo burners

Tags

animal incinerators china waste incinerator container Incinerator domestic incinerator from:hiclovercom garbage incinerator garbage incinerators general waste incinerator hospital incinerators incinerador incinerate incineration of medical waste incineration of solid waste incineration process incinerator incinerator for sale incinerator manufacturer incinerator manufacturers incinerator price incinerators incinerators china incinerators for sale industrial waste incinerator laboratory incinerator large scale incinerator Medical medical incinerator medical incinerator manufacturers medical waste medical waste incineration medical waste incinerator medical waste incinerator for sale medical waste incinerators Mobile Incinerator municipal solid waste incinerators municipal waste incinerator pathological waste incinerator portable incinerator small incinerator solid waste incinerator solid waste incinerators waste waste incineration waste incinerator waste incinerators

HICLOVER.COM

Waste Incinerator 2025 . Powered by WordPress