Airport and Aviation Maintenance Waste Incineration Solutions


Airport and Aviation Maintenance Waste Incineration Solutions


Airports and aviation maintenance bases generate diverse waste streams requiring strict environmental and safety controls. HICLOVER provides fixed dual-chamber incinerators with integrated flue gas washing systems, designed to meet civil aviation fire protection standards while ensuring efficient destruction of oil-based and organic waste.


Aviation and Airport Waste Characteristics

Within airport maintenance zones, aircraft hangars, medical first-aid stations, and catering centers, the daily waste mix typically includes:

  • Oil filters, used lubricants, and contaminated absorbents from maintenance operations.

  • Food residues and packaging from airline catering centers.

  • Medical and sanitary waste from airport clinics.

Such waste streams are difficult to manage using conventional disposal due to contamination with hydrocarbons, grease, and biological materials. Controlled high-temperature incineration above 1100°C ensures total destruction of pathogens and hydrocarbons, reducing emissions to safe levels.


HICLOVER System Design

HICLOVER’s fixed dual-chamber incinerator configuration separates the primary combustion zone from the secondary post-combustion chamber.

  • Primary chamber: directly burns mixed solid waste, maintaining stable combustion.

  • Secondary chamber: oxidizes unburned gases, achieving complete combustion and odor control.

  • Flue gas treatment: optional wet scrubber or alkali tower neutralizes acid gases before release.

  • Automation: PLC control with temperature sensors and interlocks ensures stable operation and safe shutdown.

This structure complies with international civil aviation and environmental emission guidelines, minimizing smoke and odor near terminals and runways.


Environmental and Operational Benefits

  • Reduces waste volume by up to 95%, minimizing off-site transport.

  • Handles mixed solid and semi-solid waste, including oil residues.

  • Suitable for on-site treatment within airport maintenance or logistics areas.

  • Scalable capacity options: from 50 kg/h for small terminals to 300 kg/h for regional aviation hubs.

  • Optional diesel or natural gas burners (Riello or Italy-brand) provide reliable ignition.


Global Relevance

Airports in Africa, the Middle East, and Southeast Asia are increasingly prioritizing sustainable waste management to meet ICAO and WHO standards. HICLOVER systems align with these global objectives through containerized or fixed installations adaptable to local regulations and site constraints.

For example, smaller regional airports in East Africa or Pacific islands benefit from containerized dual-chamber incinerators, which can be shipped and installed rapidly with minimal civil works. Major international airports near coastal zones prefer fixed concrete-base models with corrosion-resistant chimneys and integrated quench towers.


Integration with HICLOVER Technologies

Learn more about HICLOVER’s industrial and medical incineration systems and accessories:


Conclusion
As aviation operations expand globally, efficient and compliant waste disposal becomes critical. HICLOVER’s airport and aviation maintenance incinerator systems provide a proven solution for managing mixed industrial and biological waste safely, protecting both airport personnel and the surrounding environmental quality.

Mobile: +86-13813931455(WhatsApp)

Email:     [email protected]     
Email:     [email protected] 

 

2025-11-09/19:58:46

Incinerator Items/Model

HICLOVER TS100(PLC)

 

Burn Rate (Average)

100kg/hour

Feed Capacity(Average)

150kg/feeding

Control Mode

PLC Automatic

Intelligent Sensor

Continuously Feeding with Worker Protection

High Temperature Retention(HTR)

Yes (Adjustable)

Intelligent Save Fuel Function

Yes

Primary Combustion Chamber

1200Liters(1.2m3)

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Burner Type

Italy Brand

Temperature Monitor

Yes

Temperature Thermometer

Corundum Probe Tube, 1400℃Rate.

Temperature Protection

Yes

Automatic Cooling

Yes

Automatic False Alarm

Yes

Automatic Protection Operator(APO)

Yes

Time Setting

Yes

Progress Display Bar

3.7 in” LCD Screen

Oil Tank

200L

Chimney Type

 Stainless Steel 304

1st. Chamber Temperature

800℃–1000℃

2nd. Chamber Temperature

1000℃-1300℃

Residency Time

2.0 Sec.

Gross Weight

7000kg

External Dimensions

270x170x190cm(Incinerator Main Body)

Burner operation

Automatic On/Off

Dry Scrubber

Optional

Wet Scrubber

Optional

Top Loading Door

Optional

Asbestos Mercury Material

None

Heat Heart Technology(HHT)

Optional

Dual Fuel Type(Oil&Gas)

Optional

Dual Control Mode(Manual/Automatic)

Optional

Temperature Record

Optional

Enhanced Temperature Thermometer

Optional

Incinerator Operator PPE Kits

Optional

Backup Spare Parts Kits

Optional

Mobile Type

Optional:Containerized/Trailer/Sledge Optional