Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.)
Operational SpecsPhysical Specs Combustion Chamber Volume (m3)8.80m3 Burn Rate*up to 1,500kg per hour Average Fuel Consumption65 kg per hour or more (7 diesel burners) Operational Temperature850 – 1320°C Gas Retention in Secondary ChamberLarge secondary chamber Temperature MonitoringYes Average ash residue (%)3% Thermostatic DeviceYes 1000l diesel flue tank Venture gas scrubber Hydraulic Ram Feeding System Diesel Powered Large Incinerator Minimum Specification Required
Standards 1) Bidder or Manufacturer ISO 9001 Certified 2) Respecting international emission standards Electrical characteristics 3) A 230V, 60Hz single-phase electrical source. 4) Protections against over-voltage and over-current line conditions. 5) Compliance with applicable Ghanaian standards and regulations. Operational characteristics 6) Two-stage incineration with dual chamber combustion 7) Burn rate: 15 – 20 Kg/h 8) Capacity: not less than 130 L 9) Concentrations of most pollutants in stack gases below detection limits 10) Diesel fuel 11) Electronic system control 12) Easy to operate and minimal training 13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included
PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION