incinerator Archive

A MOBILE MEDICAL WASTE INCINERATORS

Key Product Checklist Main Burning Chamber Additional Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Circumstance Smokeshaft:5.0 Meters *( upgrade to Stainless Steel, cost-free cost) Italy oil burner: 02 collections Oil Storage Tank: 150Liters Mobile Trailer for Incinerator Version YD-50C Burning …

20-30kgs of waste per human resources with water scrubber

Product Specification Variation YD-30C (customer made version) Main Product List Main Burning Chamber( Text stainless-steel) Second Combustion Chamber( Main body stainless steel) Mix-Combustion Chamber Damp Scrubber( Washing Tower)( Text stainless-steel) Incinerator Control Instance Smokeshaft:5.0 Meters *( upgrade to Stainless Steel, cost-free cost) …

hiclover 10kgs per hour incinerator

Smallest waste incinerator for small hospital  average 10kgs per hour.  with double(2) sets burner. Tools Technical Specifications Version YD-10 Feed Capability Typical 20 kgs per feed Burning Cost Regular 10 kgs per hour Burning Time per Feed 2 humans resources Voltage 220V …

Medical Incinerators Supplier in China

*** Primary combustion chamber & secondary combustion chamber *** Smoke filter chamber(dry scrubber) *** stainless steel chimney *** PLC auto. control *** Italy made oil or gas burner(diesel oil/natural gas/lpg) *** temperature display and control *** high temperature firebrick,etc Items/Model TS10(PLC) TS20(PLC) …

Hiclover waste burner

Key Features: — — — — Complete selection burner with Saved money Tiny Scale burner, Standard Small-Large Range heater, General Municipal Solid Waste Heater, Family members Pet dog and likewise Pet Cremation, Containerized Mobile Burner, High Effective Environmental Waste Burner. — Single …

Design TS30 oil ended waste tiny burner 30kgs

Model TS30 oil fired waste small incinerator 30kgs/hr. Items/Model TS30( PLC) Picture Melt Price Typical 20-30 kg/hour Feed Capacity Normal 60kg per feeding Control Establishing PLC( Programmable Thinking Controller Incinerator) Burning Chamber 330L Inner Measurements 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber …

Containerized Mobile Incinerator Version CA50

Waste Burner (Containerized Mobile Heater) Ability: Normal 50 kgs per human resources Style CA50 Inside Dimensions 100 x 80 x 70 centimeters Main Product Listing Main Burning Chamber Added Burning Chamber Smoke Filter Chamber Heater Control Situation Smokeshaft:5.0 Meters *( upgrade to …

hiclover waste burner additional components

We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, …

Mobile Cremation Instruments

Layout CA-200 Picture Burning Rate Ordinary 100 kgs/hour Key Burning Chamber 2000 Liters Extra Burning Smokeshaft Yes Feed Setting Guidebook Voltage 220V Power 3.0 Kw Fuel Kind Diesel Oil Heater Italy Original Oil Use (Diesel Oil) Normal 53 kg/hour Inside Dimensions 230 …

Medical Center Waste Monitoring

Hospital Waste Management as well as Competitive prices as Pakistan is a competitive market. We have a complete setup with Office, Customer Relations, Import / Export, Biomedical Department, Application Support Department & Project Designing Department.Description        Minimum Requirements Design standard    Multiple chamber …

dispose Medical waste IV

the incinerator can be made use of to do away with Clinical waste IV, used needles, utilized syringes, scalpels, made use of dressing product, private security gadgets like gown, gloves and so on truncated body components, excreta from clients and also various …

STRONG WASTE BURNER

Primary chamber – Consists of a monolithic high grade refractory concrete with high grade insulation backing, . Utilising a refractory hearth or equivalent for continuous ash removal. Secondary Chamber – Consists of high density, low thermal mass refractory ceramic fibre with an …

dual chamber burner

Waste calorific worth: 4000KCAL/KG Moisture Web content: 10-25%. Small Ability: 50Kg/Hour set load. Additional Chamber: 2 Secs @ 850degrees C The main burning chamber must make certain very little separation temperature degree is not much less than 850 degrees C. INSULATION. Calcium …

nanjing clover incinerator price

Significant incinerators – – – – INDUSTRIAL INCINERATORS – – – specifications listed below. 2.) Measurement requirement for the heaters is 750 — — — — 850 kg ability 3.) The bum price require to be 80 LL 100 kg/ hour. 4) …

healthcare facility burner

Supply, arrangement and also screening of medical waste burner with an ability of 75 kg/ human resources gas (LPG) total amount with all devices and also as a result with the chimney based on the technical specs along with problems of public …

pet burners up for sale

SMART ASH INCINERATORS FOR THE DISPOSAL OF HAZARDOUS WASTE ? Quantity: 20 systems ? The Burner collaborates with a 55 gallon open ended up steel drum ? The system operates without fuel as well as used just 120v or 220v electric power …

tiny range burner

It must have the capacity to run not less than 10 hours/day This burner must be able to wreck all flammable wastes produced by medical centers, personal facilities, study laboratories, institutes, and also so on. 400 and its elevation: 8 m The …

clinical incinerators

● Able to drop 25-30kg per hour ● Contain 2 chambers to ensure significant decline in exhaust ● Be capable of temperature degree in series of 800c to 1000c ● Low upkeep style ● Has to be Fuel ● Required greater than …

laboratory heater

the entire carcass of animals (cattle, steeds, Sheep, pigs, and more), along with normally contaminated materials Products in the gas stove. ? Opening Doors – – – – the closure as well as additionally dependency automatic system, Which are dealt with from …

medical incinerator producer

1. The double chamber incinerator shall ideally be made. Air supply in the primary and secondary chamber shall be controlled in between 30% -80% as well as 170% -120% of stoichiometric amount specifically. Circulation meter/suitable circulation measurement tool shall be supplied on …

burner manufacturers

1. SCOPE OF FEATURE The work specified in the agreement will certainly consist of. 1. Supply, place as well as assign a heater as given in the technological specifications 2. Specification for adherence to OSHA along with other legal demand associating with …

Hazardous Waste Incinerators

Basic Info. Model NO.:furnace for incineration of animal waste Export Markets:Global Product Description Key Features:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime. *according to order  * High temperature, long lifetime of incinerator.  * Free or minimum …